/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IBPSA_latest_IBPSA_Fluid_Movers_BaseClasses_Validation_NegativePressureOrFlow_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=50 --tolerance=1e-06 IBPSA_latest_IBPSA_Fluid_Movers_BaseClasses_Validation_NegativePressureOrFlow.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.Movers.BaseClasses.Validation.NegativePressureOrFlow" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.Movers.BaseClasses.Validation.NegativePressureOrFlow" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.Movers.BaseClasses.Validation.NegativePressureOrFlow/model-k2swrk8p" info: *** FMU Simulation Info *** - model: model (model exchange) - path: IBPSA_latest_IBPSA_Fluid_Movers_BaseClasses_Validation_NegativePressureOrFlow.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 1.440000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | debug | Solving non-linear system 123 failed at time=3009.60000000009. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.Movers.BaseClasses.Validation.NegativePressureOrFlow/model-k2swrk8p/temp/0001_IBPSA_latest_IBPSA_Fluid_Movers_BaseClasses_Validation_NegativePressureOrFlow/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStepCVODE] fmi2_completedIntegratorStep failed for FMU "model.root.IBPSA_latest_IBPSA_Fluid_Movers_BaseClasses_Validation_NegativePressureOrFlow" warning: Bad return code at time 3009.600000 LOG_ASSERT | debug | Solving non-linear system 123 failed at time=3009.60000000009. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.Movers.BaseClasses.Validation.NegativePressureOrFlow/model-k2swrk8p/temp/0001_IBPSA_latest_IBPSA_Fluid_Movers_BaseClasses_Validation_NegativePressureOrFlow/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable eff.per.powerOrEfficiencyIsHydraulic error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 2094 NumRhsEvals = 2095 NumLinSolvSetups = 109 NumNonlinSolvIters = 2094 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 5 errors