/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IBPSA_latest_IBPSA_Fluid_HeatPumps_Validation_ScrollWaterToWater_ScalingFactor_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --timeout=50 --tolerance=1e-06 IBPSA_latest_IBPSA_Fluid_HeatPumps_Validation_ScrollWaterToWater_ScalingFactor.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_ScalingFactor" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_ScalingFactor" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_ScalingFactor/model-8zrnicka" info: *** FMU Simulation Info *** - model: model (model exchange) - path: IBPSA_latest_IBPSA_Fluid_HeatPumps_Validation_ScrollWaterToWater_ScalingFactor.fmu - startTime: 0.000000 - stopTime: 1000.000000 - tolerance: 0.000001 - stepSize: 0.400000 info: maximum step size for 'model.root': 0.400000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | debug | Division by zero 345.25 / T in function context LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 500. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | debug | Division by zero 345.25 / T in function context LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 500. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors