Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.SVarC.SVarCLoadVarQLarge.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001387/0.001387, allocations: 105.3 kB / 16.45 MB, free: 6.504 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001417/0.001417, allocations: 191.7 kB / 19.41 MB, free: 3.68 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.451/1.451, allocations: 207.6 MB / 229.8 MB, free: 11.43 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo): time 0.5856/0.5856, allocations: 103 MB / 384.6 MB, free: 20.39 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Dynawo.Examples.SVarC.SVarCLoadVarQLarge,fileNamePrefix="Dynawo_dev_Dynawo_Examples_SVarC_SVarCLoadVarQLarge",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.SVarC.SVarCLoadVarQLarge,fileNamePrefix="Dynawo_dev_Dynawo_Examples_SVarC_SVarCLoadVarQLarge",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002067/0.002067, allocations: 75.88 kB / 0.5388 GB, free: 9.641 MB / 462.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3665/0.3685, allocations: 75.63 MB / 0.6126 GB, free: 13.03 MB / 462.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SVarC.SVarCLoadVarQLarge): time 0.004964/0.3735, allocations: 5.137 MB / 0.6177 GB, free: 7.863 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.003592/0.3771, allocations: 2.947 MB / 0.6205 GB, free: 4.902 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0003974/0.3775, allocations: 15.94 kB / 0.6206 GB, free: 4.887 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/ModeHandling.mo:34:3-35:199:writable] Warning: Connector mode is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/ModeHandling.mo:36:3-36:116:writable] Warning: Connector modeAuto is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/ModeHandling.mo:37:3-37:115:writable] Warning: Connector modeManual is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/CalculationBG.mo:28:3-29:205:writable] Warning: Connector mode is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005433/0.378, allocations: 202.1 kB / 0.6207 GB, free: 4.691 MB / 462.1 MB Notification: Performance of NFTyping.typeBindings: time 0.000531/0.3786, allocations: 258.2 kB / 0.621 GB, free: 4.438 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQLarge.mo:38:3-38:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQLarge.mo:40:3-40:56:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQLarge.mo:41:3-41:56:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQLarge.mo:43:3-43:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.001516/0.3801, allocations: 0.9515 MB / 0.6219 GB, free: 3.488 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Sources/InjectorBG.mo:40:3-40:78:writable] Error: Parameter sVarCStandard.injector.G0Pu has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0002506/0.3803, allocations: 254.9 kB / 0.6222 GB, free: 3.242 MB / 462.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.2636110056191683] Failed to read output from testmodel.py, exit status != 0: 0.38660169392824173 0.399564428 -1.0 Calling exit ...