Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_1.6.1_Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00138/0.00138, allocations: 104.9 kB / 16.45 MB, free: 6.445 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001627/0.001627, allocations: 187.7 kB / 19.4 MB, free: 3.66 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.429/1.429, allocations: 207.6 MB / 229.8 MB, free: 4.25 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/package.mo): time 0.4169/0.4169, allocations: 72.85 MB / 354.5 MB, free: 12.64 MB / 286.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.6.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B2,fileNamePrefix="Dynawo_1_6_1_Dynawo_Examples_SMIB_Standard_GovSteam1ExcIEEEST4BPssIEEE2B2",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B2,fileNamePrefix="Dynawo_1_6_1_Dynawo_Examples_SMIB_Standard_GovSteam1ExcIEEEST4BPssIEEE2B2",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002273/0.002273, allocations: 75.55 kB / 0.4983 GB, free: 24.04 MB / 382.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1252/0.1274, allocations: 67.85 MB / 0.5645 GB, free: 9.016 MB / 430.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B2): time 0.0104/0.1378, allocations: 7.736 MB / 0.5721 GB, free: 1.238 MB / 430.1 MB Notification: Performance of NFInst.instExpressions: time 0.00768/0.1455, allocations: 4.244 MB / 0.5762 GB, free: 12.98 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0007988/0.1463, allocations: 23.94 kB / 0.5762 GB, free: 12.95 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:24:3-24:104:writable] Warning: Connector omegaRefPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:25:3-25:94:writable] Warning: Connector PmPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:26:3-26:125:writable] Warning: Connector efdPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:29:3-29:96:writable] Warning: Connector omegaPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:42:3-42:108:writable] Warning: Connector UStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:43:3-43:115:writable] Warning: Connector IStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:44:3-44:116:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:45:3-45:126:writable] Warning: Connector QStatorPuQNom is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:46:3-46:123:writable] Warning: Connector IRotorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:47:3-47:95:writable] Warning: Connector thetaInternal is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001197/0.1475, allocations: 361.1 kB / 0.5766 GB, free: 12.6 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.001241/0.1487, allocations: 472.6 kB / 0.577 GB, free: 12.13 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Examples/SMIB/Standard/GovSteam1ExcIEEEST4BPssIEEE2B2.mo:116:3-116:54:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Examples/SMIB/Standard/GovSteam1ExcIEEEST4BPssIEEE2B2.mo:117:3-117:54:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Examples/SMIB/Standard/GovSteam1ExcIEEEST4BPssIEEE2B2.mo:119:3-119:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:133:3-133:117:writable] Warning: In relation generatorSynchronous.SNom <> generatorSynchronous.PNomAlt, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.003214/0.152, allocations: 1.604 MB / 0.5786 GB, free: 10.54 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:51:3-51:114:writable] Error: Parameter generatorSynchronous.MdPPuEfd has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0001917/0.1521, allocations: 115.3 kB / 0.5787 GB, free: 10.42 MB / 446.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.974804086610675] Failed to read output from testmodel.py, exit status != 0: 0.15824885293841362 0.171651523 -1.0 Calling exit ...