/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.OnePhaseFlow.Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop_res.mat --tempDir=temp_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_OnePhaseFlow_Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop_fmu --startTime=0 --stopTime=500000 --stepSize=9.9942 --timeout=50 --tolerance=1e-06 ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_OnePhaseFlow_Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.OnePhaseFlow.Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.OnePhaseFlow.Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.OnePhaseFlow.Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop/model-n9ig2zpm" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_OnePhaseFlow_Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop.fmu - startTime: 0.000000 - stopTime: 500000.000000 - tolerance: 0.000001 - stepSize: 9.994200 LOG_STDOUT | warning | Error solving linear system of equations (no. 7169) at time 0.000000. LOG_STDOUT | warning | Solving linear system 7169 fails at time 0. For more information use -lv LOG_LS. LOG_ASSERT | debug | Solving linear system 7169 failed at time=0. | | | | For more information please use -lv LOG_LS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.OnePhaseFlow.Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop/model-n9ig2zpm/temp/0001_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_OnePhaseFlow_Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_OnePhaseFlow_Test_Pipe_L1_TML_LongDistanceAndGravitationalPressureDrop" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors