/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ClaRa_ClaRa.Components.Sensors.Check.TestSensors_res.mat --tempDir=temp_ClaRa_ClaRa_Components_Sensors_Check_TestSensors_fmu --startTime=0 --stopTime=2 --stepSize=0.0008 --timeout=50 --tolerance=1e-06 ClaRa_ClaRa_Components_Sensors_Check_TestSensors.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.Sensors.Check.TestSensors" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.Sensors.Check.TestSensors" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.Sensors.Check.TestSensors/model-hdvyp3el" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ClaRa_ClaRa_Components_Sensors_Check_TestSensors.fmu - startTime: 0.000000 - stopTime: 2.000000 - tolerance: 0.000001 - stepSize: 0.000800 info: model doesn't contain any continuous state LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.2-main/Components/BoundaryConditions/BoundaryGas_Txim_flow.mo:48:3-48:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundaryGas_Txim_flow.s_port >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundaryGas_Txim_flow.s_port, has value: -67.8273" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.2-main/Components/BoundaryConditions/BoundaryGas_pTxi.mo:46:3-46:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundaryGas_pTxi.s_port >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundaryGas_pTxi.s_port, has value: -67.8273" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.2-main/Components/BoundaryConditions/BoundaryGas_Txim_flow.mo:48:3-48:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundaryGas_Txim_flow1.s_port >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundaryGas_Txim_flow1.s_port, has value: -67.8273" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.2-main/Components/BoundaryConditions/BoundaryGas_pTxi.mo:46:3-46:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundaryGas_pTxi1.s_port >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundaryGas_pTxi1.s_port, has value: -67.8273" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/BaseClasses/PartialGas_pT.mo:44:3-44:56:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sensorGas_L1_V_flow.gas.p_i[10] >= 0.0)) --> "Variable violating min constraint: 0.0 <= sensorGas_L1_V_flow.gas.p_i[10], has value: -2.0303e-12" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/BaseClasses/PartialGas_pT.mo:44:3-44:56:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sensorGas_L1_V_flow.gasN.p_i[10] >= 0.0)) --> "Variable violating min constraint: 0.0 <= sensorGas_L1_V_flow.gasN.p_i[10], has value: -2.0303e-12" info: maximum step size for 'model.root': 0.000800 info: Result file: ClaRa_ClaRa.Components.Sensors.Check.TestSensors_res.mat (bufferSize=1) info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow1.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_Txim_flow2.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi1.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryGas_pTxi2.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_Txim_flow.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_Txim_flow.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_Txim_flow.steam_a.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_Txim_flow.steam_a.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_phxi.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_phxi.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_phxi.steam_a.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.boundaryVLE_phxi.steam_a.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.inlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.outlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_Ex_flow.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.gas.gasType.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.port.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_O2dry.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.port.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_T.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gas.gasType.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.gasN.gasType.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.inlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.outlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gas.gasType.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.gasN.gasType.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.inlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.outlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_V_flow1.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.inlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow.outlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.inlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.outlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_m_flow1.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.port.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorGas_L1_p.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_Ex_flow.inlet.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_Ex_flow.inlet.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_Ex_flow.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_Ex_flow.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_Ex_flow.outlet.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_Ex_flow.outlet.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_Ex_flow.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_T.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_T.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_T.port.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_T.port.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_T.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_m_flow.inlet.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_m_flow.inlet.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_m_flow.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_m_flow.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_m_flow.outlet.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_m_flow.outlet.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_m_flow.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_p.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_p.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_p.port.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_p.port.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.sensorVLE_L1_p.unit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.airModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.flueGasModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.fluid1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.fluid1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.fluid2.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.fluid2.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.fluid3.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ClaRa_ClaRa_Components_Sensors_Check_TestSensors.simCenter.fluid3.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 1126 NumRhsEvals = 1127 NumLinSolvSetups = 58 NumNonlinSolvIters = 1126 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors