/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.Movers.Validation.ControlledFlowMachineDynamic_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_Movers_Validation_ControlledFlowMachineDynamic_fmu --startTime=0 --stopTime=600 --stepSize=0.24 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_Movers_Validation_ControlledFlowMachineDynamic.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.Movers.Validation.ControlledFlowMachineDynamic" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.Movers.Validation.ControlledFlowMachineDynamic" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.Movers.Validation.ControlledFlowMachineDynamic/model-5ctsmvp1" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_Fluid_Movers_Validation_ControlledFlowMachineDynamic.fmu - startTime: 0.000000 - stopTime: 600.000000 - tolerance: 0.000001 - stepSize: 0.240000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eta, has value: -2.19301e-30" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.heaDis.etaHyd, has value: -6.6885e-27" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eff.yMot, has value: -2.79208e-32" info: maximum step size for 'model.root': 0.240000 info: Result file: Buildings_latest_Buildings.Fluid.Movers.Validation.ControlledFlowMachineDynamic_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors