/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.MSLAIT2Nodes_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_MSLAIT2Nodes_fmu --startTime=0 --stopTime=603900 --stepSize=241.56 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_MSLAIT2Nodes.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.MSLAIT2Nodes" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.MSLAIT2Nodes" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.MSLAIT2Nodes/model-vqac12of" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_MSLAIT2Nodes.fmu - startTime: 0.000000 - stopTime: 603900.000000 - tolerance: 0.000001 - stepSize: 241.560000 LOG_STDOUT | info | ... loading "dat" from "/tmp/fmi4c_dI4ZB2/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Resources/Data/Fluid/FixedResistances/Validation/PlugFlowPipes/PipeDataAIT151218.mos" info: maximum step size for 'model.root': 241.560000 info: Result file: Buildings_latest_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.MSLAIT2Nodes_res.mat (bufferSize=1) info: Variable model.root.Buildings_latest_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_MSLAIT2Nodes.DataReader.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_MSLAIT2Nodes.DataReader.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_MSLAIT2Nodes.pipeDataAIT151218.filNam will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 31 NumRhsEvals = 37 NumLinSolvSetups = 14 NumNonlinSolvIters = 36 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors