/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost/model-fmqbbi63" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost.fmu - startTime: 0.000000 - stopTime: 172800.000000 - tolerance: 0.000001 - stepSize: 69.120000 LOG_STDOUT | info | ... loading "EnergyPlus" from "/tmp/fmi4c_EyCwJU/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Resources/Data/Fluid/DXSystems/Heating/AirSource/Validation/SingleSpeedHeating_TimedResistiveDefrost/DXCoilSystemAuto.dat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" warning: [fmi2Warning] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost/model-fmqbbi63/temp/0001_Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/DXSystems/Cooling/BaseClasses/Functions/warnIfPerformanceOutOfBounds.mo:18: *** Warning: DX coil performance curves at nominal conditions are outside of bounds. Capacity as a function of temperature is outside of bounds 0.9 to 1.1. The value of the curve fit is 11.9899 Check the coefficients of the function sta[1].perCur.capFunT. info: maximum step size for 'model.root': 69.120000 info: Result file: Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost_res.mat (bufferSize=1) info: Variable model.root.Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost.datRea.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:138:7-151:38:writable] | | | | The following assertion has been violated at time 36000.000004 | | | | ((not (sinSpeDX.dxCoi.TConIn > sinSpeDX.dxCoi.coiCap.sta[sinSpeDX.dxCoi.coiCap.stage].perCur.TConInMax or sinSpeDX.dxCoi.TConIn < sinSpeDX.dxCoi.coiCap.sta[sinSpeDX.dxCoi.coiCap.stage].perCur.TConInMin))) --> "*** Warning: Condenser temperature TConIn is out of bounds in DX coil model at time = 36000. | | | | stage = 1 | | | | TConInMin = 290.93 Kelvin (17.78 degC) | | | | TConIn = 285.01 Kelvin (11.86 degC) | | | | TConInMax = 296.48 Kelvin (23.33 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 0 errors