/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.DHC.Examples.Steam.SingleBoiler_res.mat --tempDir=temp_Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Examples.Steam.SingleBoiler" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Examples.Steam.SingleBoiler" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Examples.Steam.SingleBoiler/model-ww19v1vp" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[3].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[3].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[2].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[2].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[1].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[1].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[1].sta_a.T >= 1.0 and bld[1].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[1].sta_a.T <= 1e4, has value: -918.506" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[2].sta_a.T >= 1.0 and bld[2].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[2].sta_a.T <= 1e4, has value: -918.506" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[3].sta_a.T >= 1.0 and bld[3].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[3].sta_a.T <= 1e4, has value: -918.506" info: maximum step size for 'model.root': 34.560000 info: Result file: Buildings_latest_Buildings.DHC.Examples.Steam.SingleBoiler_res.mat (bufferSize=1) info: Variable model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[1].QHea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[2].QHea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[3].QHea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[1].QHea.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[2].QHea.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[3].QHea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[1].fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[2].fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[3].fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[1].tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[2].tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Examples_Steam_SingleBoiler.bld[3].tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 2688 NumRhsEvals = 2818 NumLinSolvSetups = 181 NumNonlinSolvIters = 2817 NumNonlinSolvConvFails = 4 NumErrTestFails = 8 info: 2 warnings info: 0 errors