/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms_res.mat --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms/model-apkuakce" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.fmu - startTime: 0.000000 - stopTime: 7200.000000 - tolerance: 0.000001 - stepSize: 2.880000 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 2.880000 info: Result file: Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms_res.mat (bufferSize=1) info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.higTemAla2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.higTemAla3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla4.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla5.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 1602.240000 | | | | ((not zonAla.tenMinDur4.y)) --> "Warning: the zone CO2 concentration exceeds setpoint plus 10%." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 3762.240000 | | | | ((zonAla.not3.y)) --> "Warning: zone temperature is 2 degC lower than the heating setpoint" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 3912.000000 | | | | ((zonAla.not4.y)) --> "Warning: zone temperature is 3 degC lower than the heating setpoint" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 4340.160000 | | | | ((zonAla.not5.y)) --> "Warning: the zone CO2 concentration exceeds 600 ppm in unoccupied mode. The CO2 sensor may be out of calibration." info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors