/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Experimental.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass_res.mat --tempDir=temp_Buildings_10_Buildings_Experimental_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass_fmu --startTime=1.0368e+07 --stopTime=1.05408e+07 --stepSize=69.12 --timeout=400 --tolerance=1e-06 Buildings_10_Buildings_Experimental_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass/model-k273nc5s" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_10_Buildings_Experimental_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass.fmu - startTime: 10368000.000000 - stopTime: 10540800.000000 - tolerance: 0.000001 - stepSize: 69.120000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in CoolingTowersWithBypass.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in CoolingTowersWithBypass.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." info: maximum step size for 'model.root': 69.120000 info: Result file: Buildings_10_Buildings.Experimental.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 24 NumRhsEvals = 31 NumLinSolvSetups = 10 NumNonlinSolvIters = 30 NumNonlinSolvConvFails = 0 NumErrTestFails = 1 info: 2 warnings info: 0 errors