/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile_fmu --startTime=0 --stopTime=11000 --stepSize=4.4 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile/model-mk18io19" info: *** FMU Simulation Info *** - model: model (model exchange) - path: BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile.fmu - startTime: 0.000000 - stopTime: 11000.000000 - tolerance: 0.000001 - stepSize: 4.400000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Technologies/ThermalStorages/BaseClasses/BuoyancyModels/Buoyancy1.mo:11:3-12:165:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "The number of nodes used nEle is out of the validated range (between 4 and 40), see Info section of the selected buoyancy model." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senTem_bottom.warnAboutOnePortConnection)) --> "Sensor FluidStorageChargeDischargeProfile.senTem_bottom can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in FluidStorageChargeDischargeProfile.senTem_bottom." info: maximum step size for 'model.root': 4.400000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 1229 NumRhsEvals = 1230 NumLinSolvSetups = 66 NumNonlinSolvIters = 1229 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors