/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_fmu --startTime=1.0368e+07 --stopTime=1.07136e+07 --stepSize=138.24 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage/model-22v6z1gg" info: *** FMU Simulation Info *** - model: model (model exchange) - path: BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.fmu - startTime: 10368000.000000 - stopTime: 10713600.000000 - tolerance: 0.000001 - stepSize: 138.240000 LOG_STDOUT | info | ... loading "tab1" from "/tmp/fmi4c_fTY8TD/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not senTem1.warnAboutOnePortConnection)) --> "Sensor BigCollectorInstallationWithStorage.senTem1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in BigCollectorInstallationWithStorage.senTem1." info: maximum step size for 'model.root': 138.240000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Media/Antifreeze/PropyleneGlycolWater.mo:75:3-78:56:writable] | | | | The following assertion has been violated at time 10410439.680000 | | | | ((collectorInParallel.thermalCollectorInSerie[1].thermalCollector[3].vol[10].dynBal.medium.T <= 373.15)) --> " | | | | In BigCollectorInstallationWithStorage.collectorInParallel.thermalCollectorInSerie[1].thermalCollector[3].vol[10].dynBal.medium: Temperature T exceeded its maximum allowed value of 100 degC (373.15 Kelvin) | | | | as required from medium model "PropyleneGlycolWater(X_a = 0.4, property_T = 293.15)"." error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage/model-22v6z1gg/temp/0001_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStepCVODE] fmi2_completedIntegratorStep failed for FMU "model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage" warning: Bad return code at time 10410439.680000 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Media/Antifreeze/PropyleneGlycolWater.mo:75:3-78:56:writable] | | | | The following assertion has been violated at time 10410439.680000 | | | | ((collectorInParallel.thermalCollectorInSerie[1].thermalCollector[3].vol[10].dynBal.medium.T <= 373.15)) --> " | | | | In BigCollectorInstallationWithStorage.collectorInParallel.thermalCollectorInSerie[1].thermalCollector[3].vol[10].dynBal.medium: Temperature T exceeded its maximum allowed value of 100 degC (373.15 Kelvin) | | | | as required from medium model "PropyleneGlycolWater(X_a = 0.4, property_T = 293.15)"." error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage/model-22v6z1gg/temp/0001_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable booleanControl2.y error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 3426 NumRhsEvals = 6926 NumLinSolvSetups = 1257 NumNonlinSolvIters = 6925 NumNonlinSolvConvFails = 147 NumErrTestFails = 288 info: 3 warnings info: 5 errors