/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=50 --tolerance=1e-08 BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.Modular_OneRoomRadiator" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.Modular_OneRoomRadiator" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.Modular_OneRoomRadiator/model-5mww324g" info: *** FMU Simulation Info *** - model: model (model exchange) - path: BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000000 - stepSize: 34.560000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPumSou.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in Modular_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:144:3-149:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((heaPum.refCyc.refCycHeaPumCoo.mCon_flow_nominal <= heaPum.refCyc.refCycHeaPumCoo.mCon_flow_max)) --> "In Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal condenser mass flow rate (0.956023 kg/s) is bigger than the | | | | maximal value (0.841737 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:156:3-161:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((heaPum.refCyc.refCycHeaPumCoo.mEva_flow_nominal <= heaPum.refCyc.refCycHeaPumCoo.mEva_flow_max)) --> "In Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal evaporator mass flow rate (5.58642 kg/s) is bigger than the | | | | maximal value (3.03188 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." info: maximum step size for 'model.root': 34.560000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.datTab.devIde will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.devIde will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabPEle.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabPEle.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabQUse_flow.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabQUse_flow.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumHea.devIde will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapCoo.tabBou.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapCoo.tabBou.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapHea.tabBou.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapHea.tabBou.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.timTab.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator.timTab.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 700 NumRhsEvals = 721 NumLinSolvSetups = 53 NumNonlinSolvIters = 720 NumNonlinSolvConvFails = 0 NumErrTestFails = 4 info: 2 warnings info: 0 errors