/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated/model-7ah749de" info: *** FMU Simulation Info *** - model: model (model exchange) - path: BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Airflow/Multizone/MediumColumn.mo:10:3-10:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zone.airpath[2].h >= 0.0)) --> "Variable violating min constraint: 0.0 <= zone.airpath[2].h, has value: -1.4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Airflow/Multizone/MediumColumn.mo:10:3-10:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zone.airpath[1].h >= 0.0)) --> "Variable violating min constraint: 0.0 <= zone.airpath[1].h, has value: -1.4" info: maximum step size for 'model.root': 1.440000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 2546 NumRhsEvals = 2609 NumLinSolvSetups = 138 NumNonlinSolvIters = 2608 NumNonlinSolvConvFails = 1 NumErrTestFails = 1 info: 2 warnings info: 0 errors