/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=12614.4 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn" info: *** FMU Simulation Info *** - model: model (model exchange) - path: BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.fmu - startTime: 0.000000 - stopTime: 31536000.000000 - tolerance: 0.000001 - stepSize: 12614.400000 LOG_STDOUT | info | ... loading "tab1" from "/tmp/fmi4c_cq5UCv/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: maximum step size for 'model.root': 12614.400000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.ambience.weatherDataReader.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.ambience.weatherDataReader.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.ambience.weatherDataReader.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.ambience.weatherDataReader.weatherData.tabNam will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.construction.layer[3].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.construction.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.bottom.constructionData.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceiling.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceiling.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceiling.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceiling.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceiling.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceiling.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.construction.layer[3].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.construction.material[3].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.ceilingsInterior.constructionData.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionBottom.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionBottom.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionBottom.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionCeiling.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionCeiling.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionCeilingsInterior.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionCeilingsInterior.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionCeilingsInterior.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall1.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall1.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall1.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall2.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall2.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall2.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall3.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall3.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall3.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall4.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall4.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWall4.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWallsInterior.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWallsInterior.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.constructionWallsInterior.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.construction.layer[3].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.construction.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall1.constructionData.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.construction.layer[3].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.construction.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall2.constructionData.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.construction.layer[3].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.construction.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall3.constructionData.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.construction.layer[3].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.construction.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wall4.constructionData.material[3].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.construction.layer[3].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.construction.material[3].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.wallsInterior.constructionData.material[3].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.window1.heatTransfer.material.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.window2.heatTransfer.material.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.window3.heatTransfer.material.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.building.window4.heatTransfer.material.name will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=12108637.9603808. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=12188882.1518607. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=12188882.1518607. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3917 failed at time=12272104.6979933. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3917 failed at time=12272104.6979933. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=12360863.3369051. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=12360863.3369051. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=12882956.5213585. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=13053429.8462658. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=14354141.9136027. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3926 failed at time=15649978.4718085. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3926 failed at time=16780093.3472718. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3908 failed at time=16855541.0004138. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 4122 failed at time=16952595.2954172. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=18413838.3807481. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=18497490.03117. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=18586433.9573979. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | Solving non-linear system 3899 failed at time=18678761.2888848. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.fmutmp/sources/BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem_functions.c:4763: Invalid root: (-18640.3)^(-1.5) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem/model-useo36bn/temp/0001_BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem" [CVODE ERROR] CVode At t = 1.87689e+07, mxstep steps taken before reaching tout. error: [doStepCVODE] CVode failed with flag = -1 warning: Bad return code at time 18768942.170721 error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 1032 NumRhsEvals = 1238 NumLinSolvSetups = 95 NumNonlinSolvIters = 1236 NumNonlinSolvConvFails = 0 NumErrTestFails = 38 info: 3 warnings info: 40 errors