/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280_fmu --startTime=0 --stopTime=3.15396e+07 --stepSize=12615.8 --timeout=50 --tolerance=1e-06 AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case280" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case280" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case280/model-qyqv8as2" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.fmu - startTime: 0.000000 - stopTime: 31539600.000000 - tolerance: 0.000001 - stepSize: 12615.800000 LOG_STDOUT | info | ... loading "Table" from "/tmp/fmi4c_ZRrIRg/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Resources/weatherdata/Weatherdata_ASHARE140.txt" LOG_STDOUT | info | ... loading "Table" from "/tmp/fmi4c_ZRrIRg/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Resources/weatherdata/Weatherdata_ASHARE140.txt" info: maximum step size for 'model.root': 12615.800000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.ReferenceCoolingLoadOrTempMin.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.ReferenceCoolingLoadOrTempMin.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.ReferenceHeatingLoadOrTempMax.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.ReferenceHeatingLoadOrTempMax.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.Room.wallSouth.windowModel.corrSolGain.combiTable1Ds.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.Room.wallSouth.windowModel.corrSolGain.combiTable1Ds.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.Solar_Radiation.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.Source_Weather.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.checkResultsAccordingToASHRAECoolingOrTempMin.dispType will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.checkResultsAccordingToASHRAEHeatingOrTempMax.dispType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.dispTypeCoolOrTempMin will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.dispTypeHeatOrTempMax will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[1].FijFactors.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[2].FijFactors.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[3].FijFactors.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[4].FijFactors.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[5].FijFactors.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[1].FijFactors.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[2].FijFactors.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[3].FijFactors.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[4].FijFactors.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280.radOnTiltedSurf_Perez[5].FijFactors.tableName will not be stored in the result file, because the signal type is not supported error: [oms_RunFile] Simulation timed out - cleaning up... error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case280/model-qyqv8as2/temp/0001_AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280/logStatusError: fmi2EnterEventMode: Illegal model exchange call sequence. fmi2EnterEventMode is not allowed in model_state_terminated state. error: [doStepCVODE] fmi2_enterEventMode failed for FMU "model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case280" info: Final Statistics for 'model.root': NumSteps = 268 NumRhsEvals = 338 NumLinSolvSetups = 43 NumNonlinSolvIters = 337 NumNonlinSolvConvFails = 0 NumErrTestFails = 13