/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve_fmu --startTime=0 --stopTime=800 --stepSize=0.32 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Injection2WayValve" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Injection2WayValve" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Injection2WayValve/model-50kos124" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.fmu - startTime: 0.000000 - stopTime: 800.000000 - tolerance: 0.000001 - stepSize: 0.320000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eta, has value: -2.18545e-32" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.heaDis.etaHyd, has value: -1.8327e-29" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.yMot, has value: -2.43784e-34" info: maximum step size for 'model.root': 0.320000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipe7.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Injection2WayValve.Injection.pipeModel will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 378 NumRhsEvals = 379 NumLinSolvSetups = 22 NumNonlinSolvIters = 378 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors