/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Example_Admix_fmu --startTime=0 --stopTime=800 --stepSize=0.32 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Systems_HydraulicModules_Example_Admix.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Admix" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Admix" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Admix/model-o1mcmhnt" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_Systems_HydraulicModules_Example_Admix.fmu - startTime: 0.000000 - stopTime: 800.000000 - tolerance: 0.000001 - stepSize: 0.320000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Admix.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= Admix.PumpInterface.pump.eta, has value: -5.80911e-30" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Admix.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= Admix.PumpInterface.pump.heaDis.etaHyd, has value: -4.87148e-27" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Admix.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= Admix.PumpInterface.pump.eff.yMot, has value: -6.47999e-32" info: maximum step size for 'model.root': 0.320000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Admix.Admix.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Admix.Admix.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Admix.Admix.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Admix.Admix.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Admix.Admix.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Admix.Admix.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Admix.Admix.pipeModel will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 378 NumRhsEvals = 379 NumLinSolvSetups = 22 NumNonlinSolvIters = 378 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors