/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_Movers_Compressors_Examples_RotaryCompressorPressureLosses_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Fluid_Movers_Compressors_Examples_RotaryCompressorPressureLosses.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Examples.RotaryCompressorPressureLosses" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Examples.RotaryCompressorPressureLosses" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Examples.RotaryCompressorPressureLosses/model-hv3uxk8l" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_Fluid_Movers_Compressors_Examples_RotaryCompressorPressureLosses.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.000400 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Examples.RotaryCompressorPressureLosses/model-hv3uxk8l/temp/0001_AixLib_AixLib_Fluid_Movers_Compressors_Examples_RotaryCompressorPressureLosses/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Media/R134a.mo:2580: Fluid state is too close to the two-phase region (p=428632[Pa], T=283.15[K]. Pressure and temperature can not be used to determine properties in two-phase region. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Examples.RotaryCompressorPressureLosses/model-hv3uxk8l/temp/0001_AixLib_AixLib_Fluid_Movers_Compressors_Examples_RotaryCompressorPressureLosses/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.AixLib_AixLib_Fluid_Movers_Compressors_Examples_RotaryCompressorPressureLosses" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors