/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001_fmu --startTime=0 --stopTime=50000 --stepSize=100 --timeout=50 --tolerance=1e-06 AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_Generation.HP_heater_DaisyChain_case_001" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_Generation.HP_heater_DaisyChain_case_001" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_Generation.HP_heater_DaisyChain_case_001/model-w3wdemmy" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001.fmu - startTime: 0.000000 - stopTime: 50000.000000 - tolerance: 0.000001 - stepSize: 100.000000 LOG_INIT | error | The initialization problem is inconsistent due to the following equation: 0 != 0.02 = $DER.pipeline.fluidStream.w error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_Generation.HP_heater_DaisyChain_case_001/model-w3wdemmy/temp/0001_AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001/logFmi2Call: fmi2EnterInitializationMode: failed error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001" error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_Generation.HP_heater_DaisyChain_case_001/model-w3wdemmy/temp/0001_AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001/logStatusError: fmi2Terminate: Illegal model exchange call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001" failed error: [terminate] Termination of system "model.root" failed error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_Generation.HP_heater_DaisyChain_case_001/model-w3wdemmy/temp/0001_AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001/logStatusError: fmi2Terminate: Illegal model exchange call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "AES_AES_Coursework_ThermSys_Generation_HP_heater_DaisyChain_case_001" failed error: [terminate] Termination of system "model.root" failed info: 2 warnings info: 10 errors