Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.8458/0.8458, allocations: 153.8 MB / 170.2 MB, free: 13.78 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan_Qin",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan_Qin",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005035/0.0005035, allocations: 15.69 kB / 246.3 MB, free: 14.89 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.06644/0.06695, allocations: 33.34 MB / 279.7 MB, free: 15.12 MB / 238.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin): time 1.691/1.757, allocations: 311.9 MB / 0.5777 GB, free: 5.504 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.4501/2.208, allocations: 155.8 MB / 0.7298 GB, free: 0.5469 MB / 0.5762 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0005452/2.208, allocations: 9.219 kB / 0.7298 GB, free: 0.5469 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:52:3-53:83:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:56:3-57:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:58:3-60:16:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:48:3-50:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:51:3-52:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:53:3-55:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:56:3-57:83:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005867/2.209, allocations: 225.7 kB / 0.73 GB, free: 0.543 MB / 0.5762 GB Notification: Performance of NFTyping.typeBindings: time 0.000862/2.21, allocations: 493.5 kB / 0.7305 GB, free: 0.5352 MB / 0.5762 GB Notification: Performance of NFTyping.typeClassSections: time 0.003138/2.213, allocations: 1.503 MB / 0.7319 GB, free: 0.5 MB / 0.5762 GB Notification: Performance of NFFlatten.flatten: time 0.002337/2.215, allocations: 2.355 MB / 0.7342 GB, free: 0.5 MB / 0.5762 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001181/2.216, allocations: 1.026 MB / 0.7352 GB, free: 376 kB / 0.5762 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001084/2.217, allocations: 0.8974 MB / 0.7361 GB, free: 376 kB / 0.5762 GB Notification: Performance of NFSimplifyModel.simplify: time 0.001104/2.218, allocations: 1.062 MB / 0.7372 GB, free: 376 kB / 0.5762 GB Notification: Performance of NFPackage.collectConstants: time 0.0003159/2.219, allocations: 242.2 kB / 0.7374 GB, free: 376 kB / 0.5762 GB Notification: Performance of NFFlatten.collectFunctions: time 0.002354/2.221, allocations: 1.242 MB / 0.7386 GB, free: 364 kB / 0.5762 GB Notification: Performance of NFScalarize.scalarize: time 0.0003365/2.221, allocations: 0.5004 MB / 0.7391 GB, free: 364 kB / 0.5762 GB Notification: Performance of NFVerifyModel.verify: time 0.0009415/2.222, allocations: 1.031 MB / 0.7401 GB, free: 348 kB / 0.5762 GB Notification: Performance of NFConvertDAE.convert: time 0.002977/2.225, allocations: 2.889 MB / 0.7429 GB, free: 15.96 MB / 0.5919 GB Notification: Performance of FrontEnd - DAE generated: time 4.649e-06/2.225, allocations: 0 / 0.7429 GB, free: 15.96 MB / 0.5919 GB Notification: Performance of FrontEnd: time 1.694e-06/2.225, allocations: 0 / 0.7429 GB, free: 15.96 MB / 0.5919 GB Notification: Performance of Transformations before backend: time 4.558e-05/2.225, allocations: 1.812 kB / 0.7429 GB, free: 15.96 MB / 0.5919 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 508 * Number of variables: 508 Notification: Performance of Generate backend data structure: time 0.004432/2.23, allocations: 2.276 MB / 0.7451 GB, free: 14.94 MB / 0.5919 GB Notification: Performance of prepare preOptimizeDAE: time 4.183e-05/2.23, allocations: 7.188 kB / 0.7451 GB, free: 14.94 MB / 0.5919 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0002847/2.23, allocations: 282.1 kB / 0.7454 GB, free: 14.89 MB / 0.5919 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003961/2.231, allocations: 226.2 kB / 0.7456 GB, free: 14.79 MB / 0.5919 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0009026/2.231, allocations: 0.7292 MB / 0.7463 GB, free: 14.46 MB / 0.5919 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001506/2.232, allocations: 210.4 kB / 0.7465 GB, free: 14.39 MB / 0.5919 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0003879/2.232, allocations: 218.8 kB / 0.7468 GB, free: 14.39 MB / 0.5919 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.003139/2.235, allocations: 2.349 MB / 0.749 GB, free: 13.88 MB / 0.5919 GB Notification: Performance of preOpt findStateOrder (simulation): time 3.777e-05/2.235, allocations: 6.812 kB / 0.7491 GB, free: 13.88 MB / 0.5919 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001592/2.235, allocations: 87.78 kB / 0.7491 GB, free: 13.88 MB / 0.5919 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 3.395e-05/2.235, allocations: 50.59 kB / 0.7492 GB, free: 13.88 MB / 0.5919 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.003051/2.238, allocations: 2.05 MB / 0.7512 GB, free: 13.86 MB / 0.5919 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.01274/2.251, allocations: 14.55 MB / 0.7654 GB, free: 1.73 MB / 0.5919 GB Notification: Performance of preOpt comSubExp (simulation): time 0.001816/2.253, allocations: 1.037 MB / 0.7664 GB, free: 1.223 MB / 0.5919 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.001166/2.254, allocations: 0.7447 MB / 0.7671 GB, free: 0.8867 MB / 0.5919 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0006502/2.255, allocations: 0.4912 MB / 0.7676 GB, free: 496 kB / 0.5919 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.00135/2.256, allocations: 0.837 MB / 0.7684 GB, free: 48 kB / 0.5919 GB Notification: Performance of pre-optimization done (n=128): time 2.826e-06/2.256, allocations: 0 / 0.7684 GB, free: 48 kB / 0.5919 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=213): time 0.1661/2.422, allocations: 32.19 MB / 0.7999 GB, free: 10.03 MB / 0.6231 GB " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 3.9556131999997888] Failed to read output from testmodel.py, exit status != 0: 2.5823194770055125 2.5963187739999998 0.36812977699999994 Calling exit ...