python3 -m fmpy simulate --output-file BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage_res.csv --start-time 1.0368e+07 --stop-time 1.07136e+07 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 138.24 BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.fmu LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmpbvvemidp/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not senTem1.warnAboutOnePortConnection)) --> "Sensor BigCollectorInstallationWithStorage.senTem1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in BigCollectorInstallationWithStorage.senTem1." LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Media/Antifreeze/PropyleneGlycolWater.mo:71:3-74:56:writable] | | | | The following assertion has been violated at time 10373391.360000 | | | | ((collectorInParallel.thermalCollectorInSerie[1].thermalCollector[1].vol[2].dynBal.medium.T >= 252.58150201599636)) --> " | | | | In BigCollectorInstallationWithStorage.collectorInParallel.thermalCollectorInSerie[1].thermalCollector[1].vol[2].dynBal.medium: Temperature T exceeded its minimum allowed value of -20.5685 degC (252.582 Kelvin) | | | | as required from medium model "PropyleneGlycolWater(X_a = 0.4, property_T = 293.15)"." Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/__main__.py", line 4, in main() File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/command_line.py", line 169, in main result = simulate_fmu(args.fmu_filename, File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 1162, in simulateME recorder.sample(time, force=True) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 165, in sample values = getter(vr=vrs) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/fmi2.py", line 293, in getReal self.fmi2GetReal(self.component, vr, len(vr), value) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/fmi2.py", line 215, in w raise FMICallException(function=fname, status=res) fmpy.fmi1.FMICallException: fmi2GetReal failed with status 3 (error).