python3 -m fmpy simulate --output-file AixLib_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpChiller_res.csv --start-time 0 --stop-time 86400 --timeout 50 --relative-tolerance 1e-07 --interface-type ModelExchange --solver CVode --output-interval 60 AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumCoo: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 7200.000000 | | | | (((-DHCsubstationHeatingDirectCooling.pumHea.dp) <= 4e4)) --> "In DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea: Model operates with head -dp = 56776.4 Pa, | | | | exceeding the pressure allowed by the parameter DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/__main__.py", line 4, in main() File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/command_line.py", line 169, in main result = simulate_fmu(args.fmu_filename, File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 1124, in simulateME nextEventTime) = fmu.newDiscreteStates() File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/fmi2.py", line 476, in newDiscreteStates self.fmi2NewDiscreteStates(self.component, byref(eventInfo)) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/fmi2.py", line 215, in w raise FMICallException(function=fname, status=res) fmpy.fmi1.FMICallException: fmi2NewDiscreteStates failed with status 3 (error).