Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_upsideDownBottle.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001436/0.001436, allocations: 117.4 kB / 17.17 MB, free: 5.977 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001465/0.001465, allocations: 214.3 kB / 20.13 MB, free: 3.035 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.588/1.588, allocations: 230.6 MB / 253.5 MB, free: 15.11 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.6747/0.6747, allocations: 100.3 MB / 409.8 MB, free: 5.398 MB / 334.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_upsideDownBottle,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_upsideDownBottle",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_upsideDownBottle,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_upsideDownBottle",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002439/0.002439, allocations: 84.97 kB / 0.5589 GB, free: 13.96 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3595/0.362, allocations: 74.41 MB / 0.6316 GB, free: 2.426 MB / 462.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_upsideDownBottle): time 0.721/1.083, allocations: 247.9 MB / 0.8736 GB, free: 1.805 MB / 0.6544 GB Notification: Performance of NFInst.instExpressions: time 0.008031/1.091, allocations: 5.795 MB / 0.8793 GB, free: 1.773 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001262/1.092, allocations: 31.56 kB / 0.8793 GB, free: 1.773 MB / 0.6544 GB Notification: Performance of NFTyping.typeComponents: time 0.00214/1.094, allocations: 0.7901 MB / 0.8801 GB, free: 1.75 MB / 0.6544 GB Notification: Performance of NFTyping.typeBindings: time 0.00663/1.101, allocations: 2.783 MB / 0.8828 GB, free: 1.621 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.001933/1.103, allocations: 0.7543 MB / 0.8835 GB, free: 1.598 MB / 0.6544 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.485225125041325] Failed to read output from testmodel.py, exit status != 0: 1.1094795760000125 1.121676795 -1.0 Calling exit ...