Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00171/0.00171, allocations: 120 kB / 17.17 MB, free: 5.977 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002158/0.002158, allocations: 214.3 kB / 20.13 MB, free: 3.035 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.512/1.512, allocations: 230.6 MB / 253.5 MB, free: 15.09 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.6665/0.6665, allocations: 100.3 MB / 409.8 MB, free: 5.465 MB / 334.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002492/0.002492, allocations: 80.52 kB / 0.5589 GB, free: 13.96 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4411/0.4436, allocations: 74.42 MB / 0.6316 GB, free: 2.441 MB / 462.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling): time 0.7392/1.183, allocations: 273.2 MB / 0.8984 GB, free: 1.539 MB / 0.6544 GB Notification: Performance of NFInst.instExpressions: time 0.008432/1.191, allocations: 5.495 MB / 0.9037 GB, free: 1.492 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001591/1.193, allocations: 51.2 kB / 0.9038 GB, free: 1.492 MB / 0.6544 GB Notification: Performance of NFTyping.typeComponents: time 0.002464/1.195, allocations: 0.8076 MB / 0.9046 GB, free: 1.469 MB / 0.6544 GB Notification: Performance of NFTyping.typeBindings: time 0.009322/1.205, allocations: 3.264 MB / 0.9078 GB, free: 1.324 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.001101/1.206, allocations: 353.8 kB / 0.9081 GB, free: 1.305 MB / 0.6544 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.5006912389653735] Failed to read output from testmodel.py, exit status != 0: 1.2120022569433786 1.224261296 -1.0 Calling exit ...