Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001324/0.001324, allocations: 113.9 kB / 17.16 MB, free: 5.895 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001416/0.001416, allocations: 210.2 kB / 20.13 MB, free: 2.949 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.492/1.492, allocations: 230.6 MB / 253.5 MB, free: 15.09 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.6476/0.6476, allocations: 100.3 MB / 409.8 MB, free: 5.379 MB / 334.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_fillingClosedTank",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_fillingClosedTank",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002422/0.002422, allocations: 87.84 kB / 0.5589 GB, free: 13.94 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4265/0.429, allocations: 74.42 MB / 0.6316 GB, free: 2.426 MB / 462.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank): time 0.712/1.141, allocations: 263.9 MB / 0.8893 GB, free: 1.617 MB / 0.6544 GB Notification: Performance of NFInst.instExpressions: time 0.009297/1.15, allocations: 6.262 MB / 0.8954 GB, free: 1.547 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.00168/1.152, allocations: 35.88 kB / 0.8955 GB, free: 1.547 MB / 0.6544 GB Notification: Performance of NFTyping.typeComponents: time 0.002833/1.155, allocations: 0.8726 MB / 0.8963 GB, free: 1.52 MB / 0.6544 GB Notification: Performance of NFTyping.typeBindings: time 0.008928/1.164, allocations: 3.143 MB / 0.8994 GB, free: 1.379 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.003078/1.167, allocations: 1.1 MB / 0.9005 GB, free: 1.34 MB / 0.6544 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.337216206011362] Failed to read output from testmodel.py, exit status != 0: 1.1734178680344485 1.18570989 -1.0 Calling exit ...