Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankOverfilling.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001269/0.001269, allocations: 116.8 kB / 17.17 MB, free: 6 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001324/0.001324, allocations: 214.3 kB / 20.13 MB, free: 3.055 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.467/1.467, allocations: 230.6 MB / 253.5 MB, free: 15.09 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.6644/0.6644, allocations: 100.3 MB / 409.8 MB, free: 5.391 MB / 334.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankOverfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankOverfilling",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankOverfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankOverfilling",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002555/0.002555, allocations: 83.88 kB / 0.5589 GB, free: 13.96 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4113/0.4138, allocations: 74.43 MB / 0.6316 GB, free: 2.574 MB / 462.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Boundaries.Tests.TankOverfilling): time 0.7364/1.15, allocations: 256.4 MB / 0.8819 GB, free: 1.668 MB / 0.6544 GB Notification: Performance of NFInst.instExpressions: time 0.0126/1.163, allocations: 10.34 MB / 0.892 GB, free: 1.559 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001152/1.164, allocations: 40.56 kB / 0.8921 GB, free: 1.559 MB / 0.6544 GB Notification: Performance of NFTyping.typeComponents: time 0.001962/1.166, allocations: 0.6756 MB / 0.8927 GB, free: 1.539 MB / 0.6544 GB Notification: Performance of NFTyping.typeBindings: time 0.0085/1.174, allocations: 3.044 MB / 0.8957 GB, free: 1.422 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.0008987/1.175, allocations: 359.5 kB / 0.8961 GB, free: 1.402 MB / 0.6544 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.356294687022455] Failed to read output from testmodel.py, exit status != 0: 1.181516606011428 1.191937096 -1.0 Calling exit ...