/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser_res.mat --tempDir=temp_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser_fmu --startTime=0 --stopTime=10 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser/model-69hl4i7g" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.fmu - startTime: 0.000000 - stopTime: 10.000000 - tolerance: 0.000001 - stepSize: 0.010000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.mCV.displayString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.mCV1.displayString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm.massFlowString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm.massFlowUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm.pressureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm.temperatureString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm.temperatureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm1.massFlowString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm1.massFlowUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm1.pressureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm1.temperatureString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm1.temperatureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm2.massFlowString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm2.massFlowUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm2.pressureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm2.temperatureString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm2.temperatureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm3.massFlowString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm3.massFlowUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm3.pressureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm3.temperatureString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.multiSensor_Tpm3.temperatureUnit will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sensorVaporQuality.quantityString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sensorVaporQuality1.quantityString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.singleSensorSelect.quantityString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.singleSensorSelect1.quantityString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sinkA.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sinkA.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sinkB.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sinkB.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceA.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceA.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceA.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceA.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceB.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceB.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceB.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser.sourceB.displayPos4 will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Processes/Internal/PartialConductionElement.mo:55:3-55:114:writable] | | | | The following assertion has been violated at time 0.020000 | | | | ((noEvent(condenser.thermalElementB[20].inlet.m_flow > condenser.thermalElementB[1].m_flow_assert))) --> "Negative mass flow rate at inlet" error: [fmi2logger] [fmi2Error] ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser" error: [fmi2logger] [fmi2Error] ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Utilities/Streams.mo:113: The arguments u_min and u_max provided in the function call solveOneNonlinearEquation(f,u_min,u_max) do not bracket the root of the single non-linear equation 0=f(u): u_min = 190 u_max = 647 fa = f(u_min) = -699610 fb = f(u_max) = -200046 fa and fb must have opposite sign which is not the case error: [fmi2logger] [fmi2Error] ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_Condenser/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sourceB.xiFromInput error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors