/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator_fmu --startTime=0 --stopTime=300 --stepSize=0.12 --timeout=50 --tolerance=1e-06 ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.OpenLoopSimulator" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.OpenLoopSimulator" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.OpenLoopSimulator/model-kqsw1rtn" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.OpenLoopSimulator" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator.fmu - startTime: 0.000000 - stopTime: 300.000000 - tolerance: 0.000001 - stepSize: 0.120000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/Gas.mo:5:5-6:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Plant.GasOut.inlet.m_flow >= 0.0 and Plant.GasOut.inlet.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= Plant.GasOut.inlet.m_flow <= 1e5, has value: -13.25" info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/Water.mo:1352:5-1352:112:writable] | | | | The following assertion has been violated at time 0.120000 | | | | ((Plant.Boiler.WaterSide.w > (-Plant.Boiler.WaterSide.wnom) * Plant.Boiler.WaterSide.wnm)) --> "Reverse flow not allowed, maybe you connected the component with wrong orientation" error: [fmi2logger] [fmi2Error] ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/Water.mo:1352:5-1352:112:writable] | | | | The following assertion has been violated at time 0.240000 | | | | ((Plant.Boiler.WaterSide.w > (-Plant.Boiler.WaterSide.wnom) * Plant.Boiler.WaterSide.wnm)) --> "Reverse flow not allowed, maybe you connected the component with wrong orientation" error: [fmi2logger] [fmi2Error] ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator" error: [fmi2logger] [fmi2Error] ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -1.18244e+09 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] ThermoPower_ThermoPower_Examples_HRB_Simulators_OpenLoopSimulator/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable Plant.system.allowFlowReversal error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 7 errors