/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Modelica_3.2.3_Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls_res.mat --tempDir=temp_Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls_fmu --startTime=0 --stopTime=86400 --stepSize=17.2214 --timeout=50 --tolerance=1e-06 Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls/model-g5xua4u6" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 17.221400 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Modelica_3.2.3_Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls_res.mat (bufferSize=1) info: Parameter model.root.Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.NumberOfPeople.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.NumberOfPeople.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.traceDuctIn.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.traceDuctOut.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.traceVolume.substanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Air/MoistAir.mo:63:5-68:51:writable] | | | | The following assertion has been violated at time 32445.117600 | | | | ((ductIn.mediums[1].T >= 190.0 and ductIn.mediums[1].T <= 647.0)) --> " | | | | Temperature T is not in the allowed range | | | | 190.0 K <= (T =784.809 K) <= 647.0 K | | | | required from medium model "Moist air"." error: [fmi2logger] [fmi2Error] Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls" LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls/Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls.fmutmp/sources/Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls_functions.c:1567: Invalid root: (-0.212817)^(1.5) error: [fmi2logger] [fmi2Error] Modelica_3_2_3_Modelica_Fluid_Examples_TraceSubstances_RoomCO2WithControls/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable volume.use_portsData error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 5 errors