Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IDEAS_IDEAS.Buildings.Validation.Tests.Case600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001257/0.001257, allocations: 116.8 kB / 17.17 MB, free: 5.977 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001328/0.001328, allocations: 209.6 kB / 20.13 MB, free: 3.035 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.418/1.418, allocations: 230.6 MB / 253.5 MB, free: 15.11 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo): time 0.8459/0.8459, allocations: 133.9 MB / 443.5 MB, free: 13.77 MB / 350.1 MB " [Timeout remaining time 179] Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IDEAS.Buildings.Validation.Tests.Case600FF,fileNamePrefix="IDEAS_IDEAS_Buildings_Validation_Tests_Case600FF",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(IDEAS.Buildings.Validation.Tests.Case600FF,fileNamePrefix="IDEAS_IDEAS_Buildings_Validation_Tests_Case600FF",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: IDEAS requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001957/0.001957, allocations: 65.19 kB / 0.6141 GB, free: 38.32 MB / 0.4981 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.149/0.151, allocations: 85.86 MB / 0.6979 GB, free: 13.7 MB / 0.5137 GB Notification: Performance of NFInst.instantiate(IDEAS.Buildings.Validation.Tests.Case600FF): time 0.9283/1.079, allocations: 478.8 MB / 1.166 GB, free: 7.512 MB / 0.8575 GB Notification: Performance of NFInst.instExpressions: time 0.6578/1.737, allocations: 62.66 MB / 1.227 GB, free: 8.812 MB / 0.8887 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01856/1.756, allocations: 0.4967 MB / 1.227 GB, free: 8.812 MB / 0.8887 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/InterzonalAirFlow/BaseClasses/PartialInterzonalAirFlowBoundary.mo:21:3-22:72:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialZone.mo:195:3-207:27:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Zone.mo:6:3-18:28:writable] Warning: Connector propsBus is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/BoundaryWall.mo:64:3-66:71:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01848/1.774, allocations: 7.741 MB / 1.235 GB, free: 8.719 MB / 0.8887 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Templates/Interfaces/BaseClasses/Structure.mo:50:63-50:98:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Templates/Interfaces/BaseClasses/Structure.mo:50:3-52:73:writable] Error: Non-array modification '\"ThermodynamicTemperature\"' for array component 'quantity', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.0001936/1.774, allocations: 57.47 kB / 1.235 GB, free: 8.715 MB / 0.8887 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 5.19570516096428] Failed to read output from testmodel.py, exit status != 0: 2.0450101849855855 1.792095977 -1.0 Calling exit ...