/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Airflow.Multizone.Examples.CO2TransportStep" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Airflow.Multizone.Examples.CO2TransportStep" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Airflow.Multizone.Examples.CO2TransportStep/model-66l7z0ow" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Airflow.Multizone.Examples.CO2TransportStep" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenTop.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenTop can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IDEAS.Fluid.MixingVolumes`. | | | | See IDEAS.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenTop." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenWes.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenWes can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IDEAS.Fluid.MixingVolumes`. | | | | See IDEAS.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenWes." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenEas.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenEas can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IDEAS.Fluid.MixingVolumes`. | | | | See IDEAS.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenEas." info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep.CO2SenEas.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep.CO2SenTop.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep.CO2SenWes.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep.sou.substanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Media/Air.mo:147:5-148:53:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(volTop.dynBal.medium.T <= 423.15))) --> "In CO2TransportStep.volTop.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "IDEAS.Media.Air"." error: [fmi2logger] [fmi2Error] IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Media/Air.mo:147:5-148:53:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(volTop.dynBal.medium.T <= 423.15))) --> "In CO2TransportStep.volTop.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "IDEAS.Media.Air"." error: [fmi2logger] [fmi2Error] IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Media/Air.mo:147:5-148:53:writable] | | | | The following assertion has been violated at time 103.680000 | | | | ((noEvent(volEas.dynBal.medium.T <= 423.15))) --> "In CO2TransportStep.volEas.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "IDEAS.Media.Air"." error: [fmi2logger] [fmi2Error] IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Media/Air.mo:145:5-146:53:writable] | | | | The following assertion has been violated at time 103.680000 | | | | ((noEvent(volEas.dynBal.medium.T >= 200.0))) --> "In CO2TransportStep.volEas.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "IDEAS.Media.Air"." error: [fmi2logger] [fmi2Error] IDEAS_IDEAS_Airflow_Multizone_Examples_CO2TransportStep/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable volWes.use_C_flow error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 7 errors