/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --timeout=50 --tolerance=1e-08 IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator/model-xf5itfgy" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.fmu - startTime: 0.000000 - stopTime: 172800.000000 - tolerance: 0.000000 - stepSize: 69.120000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-08 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.timTab.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.timTab.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.timTab.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Media/Water.mo:63:5-64:118:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(heaPum.eva.vol.dynBal.medium.T >= 272.15))) --> "In ScrollWaterToWater_OneRoomRadiator.heaPum.eva.vol.dynBal.medium: Temperature T = 214.918 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "IBPSA.Media.Water"." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Media/Water.mo:63:5-64:118:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(heaPum.eva.vol.dynBal.medium.T >= 272.15))) --> "In ScrollWaterToWater_OneRoomRadiator.heaPum.eva.vol.dynBal.medium: Temperature T = 214.918 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "IBPSA.Media.Water"." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Fluid/HeatPumps/Compressors/BaseClasses/PartialCompressor.mo:85:3-87:42:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((heaPum.com.port_b.T > 173.15 and heaPum.com.port_b.T < 345.25)) --> "Condensing temperature must be above the minimum refrigerant temperature | | | | and below the critical temperature." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Fluid/HeatPumps/Compressors/BaseClasses/PartialCompressor.mo:88:3-90:42:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((heaPum.com.port_a.T > 173.15 and heaPum.com.port_a.T < 345.25)) --> "Evaporating temperature must be above the minimum refrigerant temperature | | | | and below the critical temperature." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable not2.y error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 7 errors