/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=50 --tolerance=1e-06 IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Airflow.Multizone.Examples.ChimneyShaftWithVolume" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Airflow.Multizone.Examples.ChimneyShaftWithVolume" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Airflow.Multizone.Examples.ChimneyShaftWithVolume/model-2e3wdnpy" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Airflow.Multizone.Examples.ChimneyShaftWithVolume" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume.mRoo_flow.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume.mRoo_flow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume.mRoo_flow.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Media/Air.mo:149:5-150:53:writable] | | | | The following assertion has been violated at time 4.320000 | | | | ((noEvent(sha.vol.dynBal.medium.T >= 200.0))) --> "In ChimneyShaftWithVolume.sha.vol.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "IBPSA.Media.Air"." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Media/Air.mo:149:5-150:53:writable] | | | | The following assertion has been violated at time 4.320000 | | | | ((noEvent(sha.vol.dynBal.medium.T >= 200.0))) --> "In ChimneyShaftWithVolume.sha.vol.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "IBPSA.Media.Air"." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Media/Air.mo:149:5-150:53:writable] | | | | The following assertion has been violated at time 5.760000 | | | | ((noEvent(sha.vol.dynBal.medium.T >= 200.0))) --> "In ChimneyShaftWithVolume.sha.vol.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "IBPSA.Media.Air"." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA master/Media/Air.mo:149:5-150:53:writable] | | | | The following assertion has been violated at time 5.760000 | | | | ((noEvent(sha.vol.dynBal.medium.T >= 200.0))) --> "In ChimneyShaftWithVolume.sha.vol.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "IBPSA.Media.Air"." error: [fmi2logger] [fmi2Error] IBPSA_latest_IBPSA_Airflow_Multizone_Examples_ChimneyShaftWithVolume/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sha.vol.use_C_flow error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 7 errors