Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.WatterHammer.Benchmark_KitagawaExperiment.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SMArtInt main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SMArtInt main/package.mo): time 0.01051/0.01051, allocations: 1.771 MB / 18.82 MB, free: 4.355 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001225/0.001225, allocations: 99.72 kB / 22.07 MB, free: 1.109 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001646/0.001646, allocations: 219.1 kB / 25.45 MB, free: 3.34 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.486/1.486, allocations: 230.6 MB / 259.2 MB, free: 13.11 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/package.mo): time 1.154/1.154, allocations: 130.6 MB / 446.3 MB, free: 14.56 MB / 350.1 MB " [Timeout remaining time 179] Using package ClaRa with version 1.9.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package SMArtInt with version 0.3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SMArtInt main/package.mo) Running command: "" <> buildModelFMU(ClaRa.Components.VolumesValvesFittings.Pipes.Check.WatterHammer.Benchmark_KitagawaExperiment,fileNamePrefix="ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_WatterHammer_Benchmark_KitagawaExperiment",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ClaRa.Components.VolumesValvesFittings.Pipes.Check.WatterHammer.Benchmark_KitagawaExperiment,fileNamePrefix="ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_WatterHammer_Benchmark_KitagawaExperiment",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 800] "Notification: SMArtInt requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ClaRa requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Automatically loaded package TILMedia 1.9.0 ClaRa due to uses annotation from ClaRa. Notification: TILMedia requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Warning: Requested package SMArtInt of version 0.5.1, but this package was already loaded with version 0.3.1. There are no conversion annotations for this version but 0.5.1 is newer than 0.3.1. There is a possibility that 0.3.1 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this. Notification: Performance of FrontEnd - loaded program: time 0.3864/0.3864, allocations: 46.15 MB / 0.6552 GB, free: 30.28 MB / 0.4982 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1621/0.5485, allocations: 89.05 MB / 0.7421 GB, free: 2.613 MB / 0.545 GB Notification: Performance of NFInst.instantiate(ClaRa.Components.VolumesValvesFittings.Pipes.Check.WatterHammer.Benchmark_KitagawaExperiment): time 0.01627/0.5648, allocations: 14.33 MB / 0.7561 GB, free: 4.223 MB / 0.5607 GB Notification: Performance of NFInst.instExpressions: time 0.03215/0.5969, allocations: 21.39 MB / 0.777 GB, free: 14.77 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.002585/0.5995, allocations: 67.5 kB / 0.7771 GB, free: 14.71 MB / 0.5919 GB Notification: Performance of NFTyping.typeComponents: time 0.004361/0.6039, allocations: 1.75 MB / 0.7788 GB, free: 12.95 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/Basics/ControlVolumes/FluidVolumes/VolumeVLE_L4_Advanced_WH_VCM.mo:223:34-223:48:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/Basics/ControlVolumes/FluidVolumes/VolumeVLE_L4_Advanced_WH_VCM.mo:223:4-223:90:writable] Error: Non-array modification '293.15' for array component 'nominal', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.00338/0.6072, allocations: 1.24 MB / 0.78 GB, free: 11.7 MB / 0.5919 GB " [Timeout remaining time 799] [Calling sys.exit(0), Time elapsed: 4.191753802995663] Failed to read output from testmodel.py, exit status != 0: 0.6136871359776706 0.627236612 -1.0 Calling exit ...