/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1/model-g7hzzb6i" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Using pre-compiled FMU /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1/model-g7hzzb6i/temp/0001_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones1.fmu LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1/spawn-FMUZoneAdapterZones1/EnergyPlus.fmu. It will not be converted to SI units. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning from EnergyPlus: "*** Test warning written by Zones1.core.&##10;" info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported LOG_STDOUT | info | 60.480 FMUZoneAdapterZones1.building: Error from EnergyPlus: Current time 6.0480000000000004E+01 is after next time event 6.0000000000000000E+01. Consider to change option 2.2204460492503131E-14. LOG_ASSERT | debug | 60.480 FMUZoneAdapterZones1.fmuZonCor: Failed to enter event mode in SpawnUtil.c, returned status is Error. error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1/logFmi2Call: internalEventUpdate: terminated by an assertion. info: 2 warnings info: 1 errors