/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu --startTime=1.5552e+07 --stopTime=1.56384e+07 --stepSize=34.56 --timeout=800 --tolerance=1e-07 Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC/model-xrbe4wtm" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC.fmu - startTime: 15552000.000000 - stopTime: 15638400.000000 - tolerance: 0.000000 - stepSize: 34.560000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-07 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.Xi[1] >= -1e-5) and noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = -0.00327104 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC" error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Utilities.mo:26: Wrong boundary mass fractions in medium "Air" in model "Boundary_pT": The boundary value X_boundary(1) = -0.00327104 is negative. It must be positive. error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable hvaCon2.mWat_flow.u error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors