/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedReverseCycleDefrost_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedReverseCycleDefrost" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedReverseCycleDefrost" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedReverseCycleDefrost/model-3c5m9g0l" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedReverseCycleDefrost" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost.fmu - startTime: 0.000000 - stopTime: 172800.000000 - tolerance: 0.000001 - stepSize: 69.120000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | ... loading "EnergyPlus" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedReverseCycleDefrost/model-3c5m9g0l/temp/0001_Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Fluid/DXSystems/Heating/AirSource/Validation/SingleSpeedHeating_TimedReverseCycleDefrost/DXCoilSystemAuto.dat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" warning: [fmi2Warning] Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/BaseClasses/Functions/warnIfPerformanceOutOfBounds.mo:18: *** Warning: DX coil performance curves at nominal conditions are outside of bounds. Capacity as a function of temperature is outside of bounds 0.9 to 1.1. The value of the curve fit is 11.9899 Check the coefficients of the function sta[1].perCur.capFunT. info: Result file: Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedReverseCycleDefrost_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost.datRea.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 28892.160000 | | | | ((noEvent(sinSpeDX.vol.dynBal.medium.Xi[1] >= -1e-5) and noEvent(sinSpeDX.vol.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = -0.0103124 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 28892.160000 | | | | ((noEvent(sinSpeDX.vol.dynBal.medium.Xi[1] >= -1e-5) and noEvent(sinSpeDX.vol.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = -0.0103124 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedReverseCycleDefrost/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sinSpeDX.on error: [SimulateSingleFMU] oms_simulate failed info: 3 warnings info: 5 errors