/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.CHPs.Validation.ThermalFollowing_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing_fmu --startTime=0 --stopTime=10000 --stepSize=4 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.CHPs.Validation.ThermalFollowing" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.CHPs.Validation.ThermalFollowing" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.CHPs.Validation.ThermalFollowing/model-slhsdx7z" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.CHPs.Validation.ThermalFollowing" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.fmu - startTime: 0.000000 - stopTime: 10000.000000 - tolerance: 0.000001 - stepSize: 4.000000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.CHPs.Validation.ThermalFollowing/model-slhsdx7z/temp/0001_Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Fluid/CHPs/Validation/MicroCogeneration.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((theFolNeg.opeMod.assWatMas.nand.y)) --> "Water flow rate is lower than the minimum!" info: Result file: Buildings_latest_Buildings.Fluid.CHPs.Validation.ThermalFollowing_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.avaSig.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.avaSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.avaSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.valDat.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing.valDat.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16.000000 | | | | ((theFol.fil.assPow.assMesDP.u)) --> "Rate of change in power output is outside boundaries!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16.000000 | | | | ((not theFol.eneCon.assFue.hys.y)) --> "Rate of change in the fuel mass flow rate is outside boundaries!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 20.000000 | | | | ((theFolNeg.fil.assPow.assMesDP.u)) --> "Rate of change in power output is outside boundaries!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 28.000000 | | | | ((not theFol.assWatTem.hys.y)) --> "Water temperature is higher than the maximum!" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 36.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T <= 403.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = 645.197 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 36.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T <= 403.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = 645.197 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 40.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T <= 403.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = 645.197 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 40.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T <= 403.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = 634.561 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_CHPs_Validation_ThermalFollowing/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable theFolNeg.theFol error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 7 errors