/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl_res.mat --tempDir=temp_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl/model-tvlonran" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(abs(coi.Q2_flow) < 836800.0 * max(0.001 * coi.bal1.vol.m_flow_small, abs(pum.motSpe.y))))) --> "In ChillerSetPointControl.coi.bal1.vol: | | | | The heat flow rate equals 1.76787e+06 W and the mass flow rate equals -2.92661e-14 kg/s, | | | | which results in a temperature difference 2.77981e+08 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(pum.vol.dynBal.medium.T <= 403.15))) --> "In ChillerSetPointControl.pum.vol.dynBal.medium: Temperature T = 495.681 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable triAndRes.swi.u2 error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 5 errors