/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1_res.mat --tempDir=temp_Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1_fmu --startTime=0 --stopTime=2e+06 --stepSize=800 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1/model-r1k9wzg4" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1.fmu - startTime: 0.000000 - stopTime: 2000000.000000 - tolerance: 0.000001 - stepSize: 800.000000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/DHC/Loads/Examples/SwissResidential_20190916.mos" info: Result file: Buildings_latest_Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1.filNam will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1.loa.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1.loa.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated at time 800.000000 | | | | ((noEvent(abs(ter[1].hex.Q2_flow) < 836800.0 * max(0.001 * ter[1].hex.bal1.vol.m_flow_small, abs(ter[1].hex.m1_flow))))) --> "In BenchmarkFlowDistribution1.ter[1].hex.bal1.vol: | | | | The heat flow rate equals -145484 W and the mass flow rate equals 0.0717456 kg/s, | | | | which results in a temperature difference 484.651 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated at time 1600.000000 | | | | ((noEvent(abs(ter[5].hex.Q2_flow) < 202908.0 * max(0.001 * ter[5].hex.bal2.vol.m_flow_small, abs(ter[5].hex.m2_flow))))) --> "In BenchmarkFlowDistribution1.ter[5].hex.bal2.vol: | | | | The heat flow rate equals 145464 W and the mass flow rate equals 0.0894923 kg/s, | | | | which results in a temperature difference 1602.14 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 1600.000000 | | | | ((noEvent(disFloHea.heaCoo.vol.dynBal.medium.T >= 272.15))) --> "In BenchmarkFlowDistribution1.disFloHea.heaCoo.vol.dynBal.medium: Temperature T = 21.7311 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable ter[5].swi.u2 error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors