/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ1Valve_res.mat --tempDir=temp_Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve_fmu --startTime=0 --stopTime=604800 --stepSize=241.92 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ1Valve" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ1Valve" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ1Valve/model-cckz7puq" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ1Valve" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve.fmu - startTime: 0.000000 - stopTime: 604800.000000 - tolerance: 0.000001 - stepSize: 241.920000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Buildings_latest_Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ1Valve_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve.bui.intGai.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve.bui.intGai.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve.bui.intGai.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 483.840000 | | | | ((noEvent(bui.disFloHea.val.vol.dynBal.medium.T <= 403.15))) --> "In CouplingRCZ1Valve.bui.disFloHea.val.vol.dynBal.medium: Temperature T = 776.99 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 725.760000 | | | | ((noEvent(bui.disFloCoo.val.vol.dynBal.medium.T >= 272.15))) --> "In CouplingRCZ1Valve.bui.disFloCoo.val.vol.dynBal.medium: Temperature T = -21.346 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 725.760000 | | | | ((noEvent(bui.disFloCoo.val.vol.dynBal.medium.T >= 272.15))) --> "In CouplingRCZ1Valve.bui.disFloCoo.val.vol.dynBal.medium: Temperature T = -21.346 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_DHC_Loads_BaseClasses_Examples_CouplingRCZ1Valve/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable bui.terUni.conHea.I.trigger error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors