/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterFlow_res.mat --tempDir=temp_Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow_fmu --startTime=0 --stopTime=900 --stepSize=0.36 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterFlow" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterFlow" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterFlow/model-7jm2tm1i" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterFlow" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow.fmu - startTime: 0.000000 - stopTime: 900.000000 - tolerance: 0.000001 - stepSize: 0.360000 info: Result file: Buildings_12_Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterFlow_res.mat (bufferSize=1) info: Variable model.root.Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow.assWatMas.assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow.runSig.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow.runSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow.runSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 300.240000 | | | | ((assWatMas.assMes.u)) --> "Water flow rate is lower than the minimum!" error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow/logStatusError: fmi2GetContinuousStates: Invalid argument states[] = NULL. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow" error: [SimulateSingleFMU] oms_simulate failed error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow/logStatusError: fmi2Terminate: Illegal co-simulation call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "Buildings_12_Buildings_Fluid_CHPs_BaseClasses_Validation_AssertWaterFlow" failed error: [terminate] Termination of system "model.root" failed info: 2 warnings info: 6 errors