/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.Examples.Tutorial.Boiler.System7_res.mat --tempDir=temp_Buildings_12_Buildings_Examples_Tutorial_Boiler_System7_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --timeout=400 --tolerance=1e-07 Buildings_12_Buildings_Examples_Tutorial_Boiler_System7.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Examples.Tutorial.Boiler.System7" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Examples.Tutorial.Boiler.System7" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Examples.Tutorial.Boiler.System7/model-pkvz2el7" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Examples.Tutorial.Boiler.System7" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_12_Buildings_Examples_Tutorial_Boiler_System7.fmu - startTime: 0.000000 - stopTime: 172800.000000 - tolerance: 0.000000 - stepSize: 69.120000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-07 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Buildings_12_Buildings.Examples.Tutorial.Boiler.System7_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 138.240000 | | | | (((-pumRad.dp) <= 4e4)) --> "In System7.pumRad: Model operates with head -dp = 78059.8 Pa, | | | | exceeding the pressure allowed by the parameter System7.pumRad.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Examples_Tutorial_Boiler_System7/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 207.360000 | | | | (((-pumBoi.dp) <= 4e4)) --> "In System7.pumBoi: Model operates with head -dp = 60762 Pa, | | | | exceeding the pressure allowed by the parameter System7.pumBoi.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Examples_Tutorial_Boiler_System7/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_12_Buildings_Examples_Tutorial_Boiler_System7" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 207.360000 | | | | ((noEvent(pumBoi.vol.dynBal.medium.T <= 403.15))) --> "In System7.pumBoi.vol.dynBal.medium: Temperature T = 1870.78 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Examples_Tutorial_Boiler_System7/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable stateGraphRoot.subgraphStatePort.suspend error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors