/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_11_Buildings_Fluid_Chillers_Examples_ElectricEIR_AirCooled_fmu --startTime=1.70208e+07 --stopTime=1.7064e+07 --stepSize=17.28 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_Chillers_Examples_ElectricEIR_AirCooled.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.Chillers.Examples.ElectricEIR_AirCooled" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.Chillers.Examples.ElectricEIR_AirCooled" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.Chillers.Examples.ElectricEIR_AirCooled/model-ohh3v9fh" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.Chillers.Examples.ElectricEIR_AirCooled" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_11_Buildings_Fluid_Chillers_Examples_ElectricEIR_AirCooled.fmu - startTime: 17020800.000000 - stopTime: 17064000.000000 - tolerance: 0.000001 - stepSize: 17.280000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Air.mo:146:5-147:57:writable] | | | | The following assertion has been violated at time 17020834.560000 | | | | ((noEvent(chi.vol1.dynBal.medium.T >= 200.0))) --> "In ElectricEIR_AirCooled.chi.vol1.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_Chillers_Examples_ElectricEIR_AirCooled/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Air.mo:146:5-147:57:writable] | | | | The following assertion has been violated at time 17020851.840000 | | | | ((noEvent(chi.vol1.dynBal.medium.T >= 200.0))) --> "In ElectricEIR_AirCooled.chi.vol1.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_Chillers_Examples_ElectricEIR_AirCooled/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_11_Buildings_Fluid_Chillers_Examples_ElectricEIR_AirCooled" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Air.mo:146:5-147:57:writable] | | | | The following assertion has been violated at time 17020851.840000 | | | | ((noEvent(chi.vol1.dynBal.medium.T >= 200.0))) --> "In ElectricEIR_AirCooled.chi.vol1.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_Chillers_Examples_ElectricEIR_AirCooled/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable greaterThreshold.y error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors