/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Examples.Tutorial.Boiler.System3_res.mat --tempDir=temp_Buildings_11_Buildings_Examples_Tutorial_Boiler_System3_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Examples_Tutorial_Boiler_System3.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.Tutorial.Boiler.System3" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.Tutorial.Boiler.System3" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.Tutorial.Boiler.System3/model-h0f43zyi" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.Tutorial.Boiler.System3" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_11_Buildings_Examples_Tutorial_Boiler_System3.fmu - startTime: 0.000000 - stopTime: 172800.000000 - tolerance: 0.000001 - stepSize: 69.120000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Buildings_11_Buildings.Examples.Tutorial.Boiler.System3_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:68:5-68:152:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(pumRad.port_a.p >= 0.0))) --> "Pressure (= -2.32089e+06 Pa) of medium "Buildings.Media.Water" is negative | | | | (Temperature = 293.15 K)" error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Examples_Tutorial_Boiler_System3/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:68:5-68:152:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((noEvent(boi.vol.p >= 0.0))) --> "Pressure (= -340782 Pa) of medium "Buildings.Media.Water" is negative | | | | (Temperature = 298.088 K)" error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Examples_Tutorial_Boiler_System3/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_11_Buildings_Examples_Tutorial_Boiler_System3" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:68:5-68:152:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((noEvent(spl1.vol.p >= 0.0))) --> "Pressure (= -5.12386e+08 Pa) of medium "Buildings.Media.Water" is negative | | | | (Temperature = 293.15 K)" error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Examples_Tutorial_Boiler_System3/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable not1.y error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors