/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.DHC.ETS.Heating.Examples.Direct_res.mat --tempDir=temp_Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Heating.Examples.Direct" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Heating.Examples.Direct" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Heating.Examples.Direct/model-e61bwhtd" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Heating.Examples.Direct" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Buildings_11_Buildings.DHC.ETS.Heating.Examples.Direct_res.mat (bufferSize=1) info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct.QHea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct.QHea.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct.QHea.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 103.680000 | | | | ((noEvent(heaETS.jun.vol.dynBal.medium.T <= 403.15))) --> "In Direct.heaETS.jun.vol.dynBal.medium: Temperature T = 514.598 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((pum.filter.y > -4.302103250478012e-5)) --> "In Direct.loa.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 4.3021e-05 | | | | ports[1].m_flow = -11.8515 | | | | " error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 138.240000 | | | | (((-pum.dp) <= 4e4)) --> "In Direct.pum: Model operates with head -dp = 4.15422e+06 Pa, | | | | exceeding the pressure allowed by the parameter Direct.pum.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_DHC_ETS_Heating_Examples_Direct/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable heaETS.con.I.trigger error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors