/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.DHC.ETS.Combined.Examples.ChillerOnly_res.mat --tempDir=temp_Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly_fmu --startTime=6.5e+06 --stopTime=7e+06 --stepSize=28.5063 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Combined.Examples.ChillerOnly" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Combined.Examples.ChillerOnly" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Combined.Examples.ChillerOnly/model-2ld0dx96" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Combined.Examples.ChillerOnly" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.fmu - startTime: 6500000.000000 - stopTime: 7000000.000000 - tolerance: 0.000001 - stepSize: 28.506300 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" info: Result file: Buildings_11_Buildings.DHC.ETS.Combined.Examples.ChillerOnly_res.mat (bufferSize=1) info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.TDisWatSup.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.TDisWatSup.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.TDisWatSup.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.filNam will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.loa.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly.loa.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 6515364.895700 | | | | ((noEvent(ets.tanChiWat.tan.vol[2].dynBal.medium.T <= 403.15))) --> "In ChillerOnly.ets.tanChiWat.tan.vol[2].dynBal.medium: Temperature T = 4527.82 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 6515364.895700 | | | | ((noEvent(ets.tanChiWat.tan.vol[2].dynBal.medium.T <= 403.15))) --> "In ChillerOnly.ets.tanChiWat.tan.vol[2].dynBal.medium: Temperature T = 4527.82 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:62:5-63:122:writable] | | | | The following assertion has been violated at time 6515393.402000 | | | | ((noEvent(ets.tanChiWat.tan.vol[3].dynBal.medium.T >= 272.15))) --> "In ChillerOnly.ets.tanChiWat.tan.vol[3].dynBal.medium: Temperature T = -3963.32 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:62:5-63:122:writable] | | | | The following assertion has been violated at time 6515393.402000 | | | | ((noEvent(ets.tanChiWat.tan.vol[3].dynBal.medium.T >= 272.15))) --> "In ChillerOnly.ets.tanChiWat.tan.vol[3].dynBal.medium: Temperature T = -3915.72 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_DHC_ETS_Combined_Examples_ChillerOnly/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable uHea.y error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 7 errors